Specifications
MTAS-192 Specifications
Table 14: MTAS-192 Specifications
Item Description
Dimensions 3 rack unit high chassis (H x W x D = 5.22" x 17.3" x 10.5")
Mounting 19" or 23" rack-mountable
Chassis Capacity 192 (2-wire) circuit packs
Line Card Capacity
Each line card contains 24 2-wire circuit ports. Up to 8 line
cards can be installed in a chassis.
Line Card Functionality
Options
Test Access only to data or POTS circuits
Splitter only
Splitter plus test access
Slots
8 available for line cards (#1-8)
1 available slot for control module card (#9)
Impedance
North American : 900-600 ohms
ETSI European Harmonized
Line Card
Compliances
MT-5820 and NA-5820 line cards:
T1.413, G.992.1, G.992.3, G.992.5
EU-5807 line card:
TS 101 952-1-1, TS 101 952-1-2
Test Access Capacity
2 four-wire test buses per chassis or daisy-chained system.
Each bus carries both the DSLAM/EQUIPMENT side and
the LINE/FACILITY side of the port under test.